Stops all monitors associated with the board.

Syntax

err = hil_monitor_stop_all(board_handle)
    

Description

Stops all monitors associated with the board. Stopping a monitor does not delete it. Use the hil_monitor_delete_all function to free the resources associated with all the monitor. A monitor that has been stopped, but not deleted, may be restarted using the hil_monitor_start function

If no err output is provided then it throws an exception if an error occurs. In generated code it prints the error message. Use hil_get_error_message to get the message associated with an error code.

Parameters

board_handle

The board handle returned by the hil_open function.

Outputs

err

A negative error code or zero on success.

Examples

hil_monitor_stop_all(board);   % Stop all monitors