quanser.hardware.hil.read_digital_buffer
Reads the specified number of samples from the digital channels at the indicated sampling rate.
[values, samples_read, err] = board.read_digital_buffer(clock, frequency, samples, channels)
Reads the specified number of samples from the digital channels at the indicated sampling rate. The clock parameter indicates the clock to use as a timebase. This function outputs the values read as a matrix, in which there is one row for each channel, and one column for each sample. The channels appear in the rows of the output matrix in the same order that they are specified in the channels parameter.
Many cards allow the digital I/O lines to be programmed as inputs or outputs. The digital I/O lines are configured as inputs or outputs using the set_digital_directions function. All the channels which will be used as digital inputs must be configured as inputs using this function. Failure to configure the digital I/O may result in the read_digital_buffer function failing to read those inputs.
If no err output is provided then it throws an exception if an error occurs. In generated code it prints the error message. Use hil_get_error_message to get the message associated with an error code.
board
The board instance returned by the quanser.hardware.hil.open function.
clock
The clock to use as a timebase for the buffered operation. Hardware clocks are
numbered incrementally starting at 0, with 0 meaning HARDWARE_CLOCK_0
, 1
meaning HARDWARE_CLOCK_1
, etc. The number of clocks available depends on
the board selected. Refer to
Clocks for more information.
Select a board type from the list for board-specific details: .
frequency
The number of samples per second to collect from the specified channels. At each sampling instant, all indicated channels are read.
samples
The number of samples to collect from the specified channels. One sample consists of all the indicated channels.
channels
A vector of channel numbers. Channel numbers are zero-based.
Select a board type from the list for board-specific details: .
values
A matrix of digital values, as int8s. There is one row for each channel and one column for each sample.
samples_read
The number of samples read. This value will equal the number of samples specified unless the operation was canceled.
err
A negative error code or zero on success.
% Reads 5000 samples of digital channels 0 and 3 at 1 kHz using SYSTEM_CLOCK_1
values = board.read_digital_buffer(-1, 1000, 5000, [0 3]);