Table of Contents >Quanser Rapid Control Prototyping Toolkit >VI and Function Reference >VIs - By Category >VI Categories >Utility VIs and Functions >
Owning Palette: | Utilities |
Requirements: | Quanser Rapid Control Prototyping Toolkit, LabVIEW 2020 or newer |
The Filtered Derivative VI implements the derivative of a signal and apply a low-pass filter (with configurable cut-off frequency) to the derivative.
u is the input signal that the derivative is to be calculated. |
cutoff_frequency is the cutoff frequency (in Hz) of the low-pass filter. |
sample_time is the sample time of the control loop. |
y is the filtered derivative of the input signal. |
The Filtered Derivative VI implements the derivative of a signal and apply a low-pass filter (with configurable cut-off frequency) to the derivative.
All input/output pairs of this function have direct feedthrough behaviour.
Target |
Supported |
Comments |
---|---|---|
Yes |
Fully supported. |
Copyright © Quanser Inc. This page was generated 2021-09-24. Submit feedback to Quanser about this page.
Link to this page.