Table of Contents >Quanser Rapid Control Prototyping Toolkit >VI and Function Reference >VIs - By Category >VI Categories >Hardware VIs and Functions >Control Loop VIs >CL HIL Set Encoder Counts >
Parent Polymorphic VI: | CL HIL Set Encoder Counts |
Requirements: | Quanser Rapid Control Prototyping Toolkit, LabVIEW 2020 or newer, Control Design and Simulation Module |
Sets the value of the encoder counter.
board in is a reference to a HIL Board instance that represents the open HIL board. This input must be wired to a valid HIL Board signal, as generated by a HIL Initialize VI. |
channel is a channel number indicating the encoder input channel whose counter value is being set. |
count is the value to which the encoder counter is being set. |
board out is a copy of the HIL Board instance passed to the board in input. |
This method is useful for resetting the encoder counter to a known value during a calibration procedure.
All input/output pairs of this function have direct feedthrough behaviour.
There are currently no examples
Target |
Supported |
Comments |
---|---|---|
Yes |
Fully supported. |
Copyright © Quanser Inc. This page was generated 2021-09-24. Submit feedback to Quanser about this page.
Link to this page.